Other tests & services
In the thermal testing sector we offer the following supplementing services:
- 24/7 testing
- Two LN2 tanks (together 120,000 l) ensuring consistent testing
- Customer area directly next to the control room
- Tele-testing: Test data can be transmitted worldwide via internet using proprietary IABG software and be visualised in real time
- Measurement data recording with up to 1,000 customer data channels
- Thermal elements (type T) with cables and plugs can be provided and applied by IABG
- Provision of modular front and rear mounting gear (Standard Lemosa, Sub D)
- Provision of power supplies to operate IR radiators, heaters etc. with the possibility of control loops integrating the measurement data
- 8 cryomats with coolants to control thermal plate temperatures
- Additional LN2 circles in the test volume can be provided to the customer depending on the test facility
- QCM and RGA measurements in the test volume
- Contamination analyses (active or passive) in our own physics laboratory
- Leakage testing and leakage rate determination
- Pressure simulation test, e.g. for ascent phase simulation, on components from positive pressure (approx. 2 bar) to high vacuum conditions (pk< 10-5 mbar) and vice versa
- Mobile clean room tent ISO Clean Class 5