Qualification of the emission monitoring sampling system
The requirement
- Qualification of the sampling system for the exhaust air monitoring system in KKP1 and KKP2
- Recurring test (WKP) of the total loss factor.
- Qualification of the sampling level, adaptation of the system
The results
- Identification of the relevant parameters for the sampling system
- Characterisation of the plant-specific emission
- Conformity with the regulations (KTA 1503.1)
- Metrological verification and approval of the sampling system
The solution
- Metrological verification of the "total loss factor"
- Updates to the inspection specifications
- System re-evaluation after changes to the operating parameters
- Qualification of the sampling plane
- Adaptation & certification of the emission monitoring sampling system
The added value
- "Clean & precise" procedure for metrological qualification
- Results in accordance with regulations and standards, recognised procedure
- Individual consultation on the plant-specific / on-site system